Product Detail
|
|
Glacier-Cor Distribution System for 6" Pads |
|
|
*Note
|
|
This product is the distribution system only. The Glacier-Cor Cooling System also requires pads, plumbing, and pump. Purchasing the components separately allows you to build a 4" or 6" system to any height from 2' to 8'. For a complete 4" Glacier-Cor system at 3' high, with everything you need CLICK HERE. |
|
|
Description
|
|
 |
|
The Glacier-Cor Cooling System works together with your greenhouse fans to lower temperatures 10-25 degrees. When large quantities of air are pulled through Glacier-Cor air pads that are saturated with water, a substantial cooling effect is realized due to the evaporation of that water. Suited for virtually all geographic locations. |
|
|
Dimensions
|
|
Width = 5' to 90' (5' increments)
Height = 2', 3', 4', 5', 6', 7' or 8'
Pads Required = 6" thick x 12" wide (heights vary) |
|
|
Assembly
|
|
Evap-pad system is placed on end wall or side wall of greenhouse. Normally, the maximum distance between fans and evap-pad system is 120 ft. The evap-pad system should extend the full length of the end or side wall. For multiple fans the distance between the fans should not exceed 20 ft. to keep hot spots from developing.
|
|
|
Standard
Features
|
|
This water distribution system is composed of the water distributor PVC pipe with metered outlet holes, top and bottom pad support material, water distributor cover, water return gutter, water strainer, float valve and miscellaneous parts and fasteners. (Pads, pump, and plumbing kit not included - see accessories below.)
|
|
|
Pad Sizing Chart
|
|
Divide max pad area by individual pad square feet to obtain optimum number of Glacier-Cor pads
|
Fan Model
|
CFM @ 0.05" S.P. |
Max. 4" Pad Area (Sq. Ft.) |
Max. 6" Pad Area (Sq. Ft.) |
| NB24G |
5100 |
20 |
13 |
| NB24H |
5800 |
23 |
15 |
| NB24J |
6760 |
27 |
17 |
| NB24K |
8140 |
32 |
20 |
| NB30G |
7100 |
28 |
18 |
| NB30H |
7890 |
31 |
20 |
| NB30J |
9430 |
38 |
24 |
| NB30K |
10715 |
43 |
27 |
| NB36H |
9840 |
39 |
25 |
| NB36J |
11325 |
45 |
28 |
| NB36K |
13105 |
52 |
33 |
| N36L |
14895 |
60 |
37 |
| NB42J |
13070 |
52 |
33 |
| NB42K |
15865 |
63 |
40 |
| NB42L |
17515 |
70 |
44 |
| NB48J |
16250 |
65 |
41 |
| NB48K |
19240 |
77 |
48 |
| NB48L |
20665 |
83 |
52 |
| NB54L |
23060 |
92 |
58 |
| NB54M |
27780 |
111 |
69 |
|
|
|
Recommended
Accessories
|
|
Accessories needed to complete the Glacier-Cor Distribution System for 6" Pads - 6" thick Glacier-Cor pads, pump, and plumbing kit (see below):
|
| Glacier-Cor Distribution System Accessories |
Description |
Quantity |
|
|
6" thick x 12" wide - available in 2', 3', 4', 5', 6', 7' & 8' heights
Made of specially formulated cellulose paper, impregnated with insoluble anti-rot salts, stiffening saturants and wetting agents. |
See sizing chart
(above) |
|
|
The pump is sized for the system to supply at least 1/2 gallon of water per minute per linear foot of pad system. Use a P-20 pump for systems 20 foot or less in length. Use a P-25 pump for systems 25 to 40 feet in length. Use a P-40S pump for systems 45 to 70 foot in length and a P50 pumps for systems 75 to 90' in length. Longer systems will require 2 or more pumps.
|
1 |
|
|
To complete your installation, purchase the optional plumbing kit. It includes everything you need to plumb your Glacier-Cor System (except for the sump). The sump should be sized for at least 3/4 gallon capacity per square foot of pad area. The sump is not a standard part of the plumbing kit and must be obtained locally.
|
1 |
|
|
PDF Manual
|
|
|
|
|
Shipping
|
|
Important Shipping Information: Due to size and/or weight, this product must ship via Common Carrier instead of UPS. To obtain the correct freight charges be sure to select this shipment method upon checkout. Please phone IGC customer service at (888) 281-9337 if you have any questions regarding shipment of this product. |
|