Exhaust Shutter Fan
FA-VES-20115
No reviews
$329.00
Regular price
/
- In stock - departs in 1-2 business days
- Inventory on the way
Works with
No reviews
FA-VES-20115
This Exhaust Shutter Fan combines a heavy extruded aluminum shutter with a high performance motor and balanced blade series. Available in 12" up to 24", the heavy-duty high efficiency motor is designed to work in the harshest environment. The powder-coated intake guard is corrosion resistant, safe and strong. The heavy aluminum blade is quiet, balanced and engineered to move maximum air. The matching designed motor, blade combination makes this fan series very energy efficient. The fan comes with a 9' cord so no electrician is required for installation.
Size |
Spd | HP | Hz | Voltage | Phs | Amps H/M/L | RPM H/M/L |
---|---|---|---|---|---|---|---|
12" | Var* | 1/10 | 60 | 115 | 1 | 1.35 | 1725 |
12" | 3 | 1/10 | 60 | 115 | 1 | 0.9/0.7/0.6 | 1672/1585/1470 |
16" | Var* | 1/10 | 60 | 115 | 1 | 1.35 | 1725 |
16" | 3 | 1/10 | 60 | 115 | 1 | 1.1/0.9/0.7 | 1650/1565/1454 |
20" |
Var* | 1/3 | 60 | 115 | 1 | 4.20 | 1725 |
20" | 3 | 1/4 | 60 | 115 | 1 | 2.4/1.6/1.1 | 1570/1260/944 |
24" |
Var* | 1/2 | 60 | 115 | 1 | 4.94 | 1725 |
24" | 3 | 1/4 | 60 | 115 | 1 | 2.8/1.8/1.3 | 1564/1242/903 |
Size |
Spd | CFM 0" SP H/L or H/M/L | CFM .10" SP H/L or H/M/L | Noise DB | Rough Opening |
---|---|---|---|---|---|
12" | Var* | 1080/360 | 900/300 | 55/50 | 12.5" x 12.5" |
12" | 3 | 1000/940/880 | 800/750/570 | 52/48 | 12.5" x 12.5" |
16" | Var* | 1890/660 | 1575/550 | 55/50 | 16.5" x 16.5" |
16" | 3 | 1950/1890/1170 | 1560/1890/1170 | 54/50 | 16.5" x 16.5" |
20" | Var* | 4500/1575 | 3750/1315 | 57/52 | 20.5" x 20.5" |
20" | 3 | 4251/3246/1620 | 3400/2596/1296 | 58/53 | 20.5" x 20.5" |
24" | Var* | 5625/1970 | 4690/1640 | 58/53 | 24.5" x 24.5" |
24" | 3 | 4874/3596/1881 | 3899/2876/1504 | 60/55 | 24.5" x 24.5" |
* Variable speed fans require separate variable speed control to adjust fan speed.
How-to-Wire for Heating or Cooling
1. The first thing that you need to determine is the amount of air required. This is stated in CFM (Cubic Feet of Air per Minute).
2. Use the following formula to determine the CFM required for your greenhouse:
CFM = Length x Width x Height
Example: Greenhouse 12' wide x 24' long x 12' high requires 3456 CFM (12 x 24 x 12 = 3456)
3. Reference the above table. Select the appropriate combination of fan(s) to achieve the necessary CFM rating. Be sure to match the total CFM output for your exhaust fan(s) to the CFM ratings for your Inlet Shutters.
This item ships free via Motor Freight Carrier - almost anywhere in the Contiguous United States!
On rare occasions addresses with limited access such as islands or major metropolitan areas (ie: New York City) may incur additional delivery fees; if so, you will be contacted to confirm the extra shipping cost before your order is processed. Shipments to Alaska or Hawaii qualify for free shipping to any West Coast port. Please contact us for special shipping rates from the West Coast to Alaska or Hawaii.